Control and functions
Routing of the hydraulic lines in the loader

Routing of the hydraulic lines in the loader

The hydraulic systems of 5M iT4, 5R6MC/RC6M and 6R Tractors provide the power to activate the loader movements. The loader hydraulic lines are integrated within the boom arm which reduces the risk of damage and increases the loader visibility and maneuverability. 

 

John Deere provides a wide range of loader functions, starting with a minimum of two functions to lift and crowd the loader simultaneously. The third function configuration allows the operation of three independent functions simultaneously. With the diverter, the fourth function can be added for the operator’s utilization

 
Table: Overview of available functions
 

Number of functions

Task

Application

Two functions

Two functions can be actuated simultaneously.

Lift and crowd

 

Two functions plus diverter

Two functions can be actuated simultaneously and a diverter button allows the operation of an additional function.

Lift and crowd/open grapple

 

Three functions

Three functions can be actuated simultaneously.

Lift and crowd and open grapple

 

Three functions plus diverter

Three functions can be actuated simultaneously and a diverter button allows the operation of an additional function.

Lift and crowd and open grapple and use elevator

 
Selective control valves (SCVs)
 
SCV in the cab

SCV in the cab

SCV in the back

SCV in the back

On both the two-function and three-function loaders, the operator can find the control needed for the operation. A simple and economic solution is to connect the hydraulic hoses to the rear of the tractor, via the rear SCVs which are installed in base equipment. There is no need to install extra valves on the tractor. The operation of the rear SCVs is controlled either with the mechanical SCV (M-SCV) levers on the right-hand console, or via the electrohydraulic SCV (E-SCV) controls located on the right-hand console or on the CommandARMTM console on premium tractors.
Mechanical loader control valve (M-LCV)
 
Buttons on the mechanical joystick

Buttons on the mechanical joystick

The mechanical joystick is a more convenient way to operate the loader. The lever shape has been tested and approved to ensure easy control and access to all buttons, providing the highest ergonomic level. With a mechanical joystick, two or three independent functions can be operated at the same time. With a two-independent-functions control valve, for example, the driver can crowd the bucket while lifting the boom. When in combination with a diverter, the mechanical joystick provides the option for the operator to periodically divert control from the second function and operate a third function instead. The additional third independent function enables opening/closing the grapple which is often used for moving manure or loading silage. A lock position is possible due to a specific ring under the handle. This allows the operator to disable the valve control. The M-LCV is located below the tractor cab and enables additional control for front loader work, while maintaining the use of rear SCVs.
Electronic loader control valve (E-LCV)
 
Electronic joystick for 6R Stage IIIB (or earlier)

Electronic joystick for 6R Stage IIIB (or earlier)

The sophisticated electronic joystick offers the operator an even more comfortable and accurate loader handling. The hydraulic flow as well as the speed of the loader functions can be set with the electronic joystick. The joystick is mounted on the armrest or on the CommandARM controls and manages up to five independent functions as well as diverter valve, return-to-position (RTP) and the GSS. The electronic joystick is not compatible with the GSS if the buttons on the joystick are already being used for the diverter valve application.
 
An additional button can be placed in the cab to activate the loader suspension. A safety flap allows the operator to disable the valve activation, preventing accidental activation.
Buttons on the electrical joystick for 6M Stage IV

Buttons on the electrical joystick for 6M Stage IV

The compact electronic joystick offers various buttons for easy and comfortable use:
  1. GSS
  2. Rocker switch for three independent function operations
  3. First diverter button
  4. LSS
  5. Second diverter button
  6. Not used
  7. Lock/unlock joystick
The electronic joystick on the 5R offers reverser and gear shifting on the joystick

The electronic joystick on the 5R offers reverser and gear shifting on the joystick

Types of available controls
 
 
CodeAttachmentDescription
3011 

SCV 2F

 EC49258

Hydraulic connections to SCV 2F for 6X30 and 7X30 Premium

 BCC10051

Hydraulic connections to SCV 2F for 6105R-6125R iT4 (Stage IIIB), 6105M - 6125M Tier 2 and iT4 (Stage IIIB), 6MC/RC FT4 (Stage IV), and 6110R-6130R FT4 (Stage IV). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10061

Hydraulic connections to SCV 2F for 6130R-6210R iT4 (Stage IIIB), 6130M-6170M Tier 2 and iT4 (Stage IIIB), 6110R-6130R FT4 (Stage IV), and 6135R-6215R FT4 (Stage IV). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10052

Hydraulic connections to SCV 2F for 6170R-6210R iT4 (Stage IIIB), 6170M Tier 2 and iT4 (Stage IIIB), and 6135R-6215R FT4 (Stage IV)

 BCC10421

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6X00, 6X10, 6X20, and 6X30 Standard

 BCC10419

M-LCV 2F plus diverter (mechanical loader control valve two functions + diverter) plus GSS for 6X30 Premium

 BCC10427

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6105M-6125M Tier 2 and iT4 (Stage IIIB). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10426

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6130M-6150M Tier 2 and iT4 (Stage IIIB). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10425

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6170M Tier 2 and iT4 (Stage IIIB)

 BCC10438

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6105R-6125R iT4 (Stage IIIB)

 BCC10439

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6130R-6150R iT4 (Stage IIIB)

 BCC10431

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6170R-6210R iT4 (Stage IIIB)

 BCC10433

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6MC/RC iT4 (Stage IIIB)

 BCC10364

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6110R-6130R FT4 (Stage IV)

 BCC10369

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6135R-6155R FT4 (Stage IV)

 BCC10372

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) plus GSS for 6175R-6215R FT4 (Stage IV)

3012 

M-LCV 2F (mechanical loader control valve two functions)

3013 

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter)

3014 

M-LCV 3F (mechanical loader control valve three functions)

 BCC10422

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6X00, 6X10, 6X20, and 6X30 Standard

 BCC10420

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6X30 Premium

 BCC10424

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 7X30 Premium

 BCC10430

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6105M-6125M Tier 2 and iT4 (Stage IIIB). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10429

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6130M-6150M Tier 2 and iT4 (Stage IIIB). For Tier 2 refer DTAC Solution 106983 for serial break.

 BCC10428

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6170M Tier 2 and iT4 (Stage IIIB)

 BCC10440

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6105R-6125R iT4 (Stage IIIB)

 BCC10441

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6130R-6150R iT4 (Stage IIIB)

 BCC10432

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6170R-6210R iT4 (Stage IIIB)

 BCC10434

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6MC/RC iT4 (Stage IIIB)

 BCC10365

M-LCV 3F (mechanical loader control valve three functions) plus GSS for 6110R-6130R FT4 (Stage IV)

3023 

M-LCV 2F plus diverter (mechanical loader control valve two functions plus diverter) - loader prep

3024 

M-LCV 3F (mechanical loader control valve three functions) - loader prep

3025 

E-LCV 2F/2F + diverter (electrical loader control valve two functions/two functions plus diverter) - loader prep

3026 

E-LCV 3 F (electrical loader control valve three functions) - loader prep

3031 

Parts for control by two functions (M-LCV 2F or E-LCV 2F) - loader ready

3033 

Parts for control by two functions plus diverter valve M-LCV - loader ready

3034 

Parts for control by three functions M-LCV - loader ready

3035 

Parts for control by two functions plus diverter valve E-LCV - loader ready

3036 

Parts for control by three functions E-LCV - loader ready

 
Last Updated : 25-Sep-2018
 